Microwave Freq. : 10.525 GHz, pulsed
Input Voltage : 10 to 16 VDC, 12 VDC nominal
Pyro Type : Dual Element
Pulse Count : Jumper selectable: PC2, PC4
Warm-up Time : < 50 seconds
Alarm Period : 2.4 seconds, retriggerable
Visual Indicator : Red Alarm LED (Selectable On / Off)
Weight : 3.7 oz / 105 g
Environmental : 95% humidity non-condensing
Mounting way : Wall mounted
QT-40 Quad Element Outdoor Indoor Homelux Microwave Pir Detector With Pet Immunity for intrusion alarm
| Microwave Freq. | 10.525 GHz, pulsed | 
| Input Voltage | 10 to 16 VDC, 12 VDC nominal | 
| Input Current | 15 mA max. (SL model 30 mA), 11 mA quiescent (approx.) | 
| Pyro Type | Dual Element | 
| Pulse Count | Jumper selectable: PC2, PC4 | 
| Warm-up Time | < 50 seconds | 
| Alarm Period | 2.4 seconds, retriggerable | 
| Visual Indicator | Red Alarm LED (Selectable On / Off) | 
| Alarm Output | NC, solid state, 19 VDC, 100 mA, 13 ohms resistance typ. | 
| Tamper Output | NC, dry contact, 30 VDC, 500 mA, 5 W max. | 
| Mounting Height | 7 to 8.5 ft (2.1 to 2.6 m) | 
| Operating Temp. | 14° to 131° F (-10° to+55° C) | 
| Environmental | 95% humidity non-condensing | 
| Weight | 3.7 oz / 105 g | 
| Dimensions | 4.8” H x 2.5” W x 1.7” D / 12.2cm x 6.4cm x 4.3cm | 

Microwave Sensitivity: Microwave Sensitivity Adjustment is set to the fully clockwise position at the factory for maximum sensitivity (range). The installation in a small room, it may be desirable to reduce microwave sensitivity. Turn the Microwave Sensitivity Adjustment (Fig. 2) counter-clockwise to reduce sensitivity. Setting the adjustment to minimum (fully counter-clockwise) reduces sensitivity to approximately one-third of its maximum value.


| Trouble | Likely Causes | Remedy | 
| Unit does not power up. | No or low input power. Input power polarity reversed.  |  			Apply proper input voltage. Correct wiring polarity. | 
| Alarm LED does not light. | LED jumper is set to “LED OFF”. Incorrect sensor mounting height or aiming. Pulse count setting incorrect for protection area .  |  			Set LED jumper to“LED ENABLED”. Alter the mounting height or aim. Set pulse count jumper to suit the detection requirements.  |  		
| Alarm LED / Relaytriggers without movement in the protection area. | Animals / rodents in protection area. Heating or air conditioning outlets in sensor view. If using the optional animal immune lens: Pet access to furniture or room fixture in view of the detector.  |  			Block access of animals / rodents. Re-aim sensor. Ensure that pets can not climb up onto furniture / fixtures in protection area.  |  		
| An alarm is indicated at the LED but not at the alarm output. | Incorrect wiring at the alarm output terminals. Lightning damage.  |  			Correct the wiring fault. Replace sensor.  |  		
| Alarm LED on constantly, no fault in protected area or wiring . | Defective unit. | Replace sensor. | 
| Unit continues to operate after input power has been disconnected. | The wire to the power input was disconnected, the “+” is still connected. The power is finding a return path through the Alarm Output protection device and alarm wiring. | Disconnect wire from the “+” power input. | 
| 
                                             | 
                